PTCs operate based on the principles of the thermodynamic cycle. They use a combination of a compressor, heat exchangers, and a pulse tube to transfer heat from the cold end to the warm end. The key mechanism involves oscillating high-pressure and low-pressure gas (usually helium) through the system. The gas absorbs heat at the cold end and releases it at the warm end, which is then dissipated into the environment.